Page 7 - PMK

Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Probe Selector
Function:
All VoltageVoltage CurrentCurrent ThermalThermal OpticalOptical MagneticMagnetic AcousticAcoustic
Brand:
All IWATSU T&M Research PMK PEM CIC Research North Star High Voltage Tektronix Keysight Technologies Sapphire Instruments JC Electronics Fischer Custom Communications Vitrek Cybertek GMW Associates Pearson Electronics Nissin Pulse Electronics YOKOGAWA Danisense HIOKI HBM Hangzhi Chauvin Arnoux Tronovo MagneLab Pico Technology PINTEK HBK Teledyne LeCroy Probemart Vamtek Jectronic Instruments Siglent Technologies RIGOL Technologies UNI-T ZLG / ZHIYUAN Electronics LongSight Technologies TESTEC PM-SMS / HITEC Bergoz Fluke Universal Micsig Pomona Electronics GMC-I Messtechnik HILO TEST LEM Brüel & Kjær Bartington Instruments Elemental Instruments SENIS Ross Engineering CPS HV Multi-Contact Rohde & Schwarz Opsens Newtons4th (N4L) PCB Sensor
More Brands More Brands
B C D E F G H I J K L M N O P R S T U V Y Z
PMK PHV662-L-RO high-frequency 400M high-voltage 2800 Vrms/6 kVpk oscilloscope voltage probe (100:1)

PMK PHV662-L-RO high-frequency 400M high-voltage 2800 Vrms/6 kVpk oscilloscope voltage probe (100:1)

PMK PHV662-L-RO high-frequency 400M high-voltage 2800 Vrms/6 kVpk oscilloscope voltage probe (100:1)

Brand: PMK

Origin: Germany

PHV662-L-RO, ratio 100:1; 2m; bandwidth 400 MHz; peak voltage: 2800 Vrsm, 4000 VAC+DCpk, 6000 Vpk (Pluse); inp…

PMK PHV661-L-RO high-frequency 400M high-voltage 2800 Vrms/6 kVpk oscilloscope voltage probe (100:1)

PMK PHV661-L-RO high-frequency 400M high-voltage 2800 Vrms/6 kVpk oscilloscope voltage probe (100:1)

PMK PHV661-L-RO high-frequency 400M high-voltage 2800 Vrms/6 kVpk oscilloscope voltage probe (100:1)

Brand: PMK

Origin: Germany

PHV661-L-RO, ratio 100:1; 1.2m; bandwidth 400 MHz; voltage: 1500 V-2800Vrsm, V-4000VAC+DCpk, 6000 Vpk (Pluse);…

PMK PHV1000 series 2 kV @ 400 MHz high-frequency high-voltage oscilloscope PHV1000-RO voltage probe 2000 V (100:1)

PMK PHV1000 series 2 kV @ 400 MHz high-frequency high-voltage oscilloscope PHV1000-RO voltage probe 2000 V (100:1)

PMK PHV1000 series 2 kV @ 400 MHz high-frequency high-voltage oscilloscope PHV1000-RO voltage probe 2000 V (100:1)

Brand: PMK

Origin: Germany

PHV Series of Probes extend the measuring range of your oscilloscope to probe high voltages safely and easily.…

PMK high-low-temperature voltage probe ENVI @ PHT 835-312-Z01 probe-55 °C-155 °C high-frequency 500M/1250 Vpk

PMK high-low-temperature voltage probe ENVI @ PHT 835-312-Z01 probe-55 °C-155 °C high-frequency 500M/1250 Vpk

PMK high-low-temperature voltage probe ENVI @ PHT 835-312-Z01 probe-55 °C-155 °C high-frequency 500M/1250 Vpk

Brand: PMK

Origin: Germany

ENVI® passive probe non- test, and-55°C to +155°C medium- measurement. 835-312-Z01 PHT:-55°C to 155°C

PMK dedicated power supply PS-02 high-frequency differential probe powered PS-03 4-channel optically isolated /Bumblebee/HSDP for

PMK dedicated power supply PS-02 high-frequency differential probe powered PS-03 4-channel optically isolated /Bumblebee/HSDP for

PMK dedicated power supply PS-02 high-frequency differential probe powered PS-03 4-channel optically isolated /Bumblebee/HSDP for

Brand: PMK

Origin: Germany

For PMK voltage probe

PMK pulse current probe LILCO series CT dedicated attenuator ATT10BNCS attenuation 10: 1 (20 dB)

PMK pulse current probe LILCO series CT dedicated attenuator ATT10BNCS attenuation 10: 1 (20 dB)

PMK pulse current probe LILCO series CT dedicated attenuator ATT10BNCS attenuation 10: 1 (20 dB)

Brand: PMK

Origin: Germany

Fixtures & Accessories. Detailed specifications are available in the product datasheet.

PMK LILCO current probe 89M0100 precision wideband RF transformer-pulse CT 5000 A/10 MHz

PMK LILCO current probe 89M0100 precision wideband RF transformer-pulse CT 5000 A/10 MHz

PMK LILCO current probe 89M0100 precision wideband RF transformer-pulse CT 5000 A/10 MHz

Brand: PMK

Origin: Germany

PMK LILCO current probe 89M0100 type: aperture 89 mm; ratio 0.1 V/A; peak 5000 A, bandwidth 0.5 Hz-10MHz; rise…

PMK LILCO current probe 58MH010 precision wideband RF transformer-pulse CT 20000 A/5 MHz

PMK LILCO current probe 58MH010 precision wideband RF transformer-pulse CT 20000 A/5 MHz

PMK LILCO current probe 58MH010 precision wideband RF transformer-pulse CT 20000 A/5 MHz

Brand: PMK

Origin: Germany

PMK LILCO current probe 58MH010 type: aperture 58 mm; ratio 0.01 V/A; peak 20000 A, bandwidth 0.04 Hz-5MHz; ri…

PMK LILCO current probe 58EH010 precision wideband RF transformer-pulse CT 20000 A/5 MHz

PMK LILCO current probe 58EH010 precision wideband RF transformer-pulse CT 20000 A/5 MHz

PMK LILCO current probe 58EH010 precision wideband RF transformer-pulse CT 20000 A/5 MHz

Brand: PMK

Origin: Germany

PMK LILCO current probe 58EH010 type: aperture 58 mm; ratio 0.01 V/A; peak 20000 A, bandwidth 0.5 Hz-5MHz; ris…

PMK LILCO current probe 58M0020 precision wideband RF transformer-pulse CT 20000 A/2 MHz

PMK LILCO current probe 58M0020 precision wideband RF transformer-pulse CT 20000 A/2 MHz

PMK LILCO current probe 58M0020 precision wideband RF transformer-pulse CT 20000 A/2 MHz

Brand: PMK

Origin: Germany

PMK LILCO current probe 58M0020 type: aperture 58 mm; ratio 0.02 V/A; peak 20000 A, bandwidth 0.06 Hz-2MHz; ri…

PMK LILCO current probe 58E0020 precision wideband RF transformer-pulse CT 20000 A/2 MHz

PMK LILCO current probe 58E0020 precision wideband RF transformer-pulse CT 20000 A/2 MHz

PMK LILCO current probe 58E0020 precision wideband RF transformer-pulse CT 20000 A/2 MHz

Brand: PMK

Origin: Germany

PMK LILCO current probe 58E0020 type: aperture 58 mm; ratio 0.02 V/A; peak 20000 A, bandwidth 0.8 Hz-2MHz; ris…

PMK LILCO current probe 58M0050 precision wideband RF transformer-pulse CT 10000 A/5 MHz

PMK LILCO current probe 58M0050 precision wideband RF transformer-pulse CT 10000 A/5 MHz

PMK LILCO current probe 58M0050 precision wideband RF transformer-pulse CT 10000 A/5 MHz

Brand: PMK

Origin: Germany

PMK LILCO current probe 58M0050 type: aperture 58 mm; ratio 0.05 V/A; peak 10000 A, bandwidth 0.15 Hz-5MHz; ri…

  • «
  • 1
  • 2
  • ...
  • 6
  • 7
  • 8
  • 9
  • 10
  • »